Product Recall: Vevor Electric Shear (2210-0070)
Product Recall for Vevor Electric Shear J1J-2.5/J1J-3.2 presenting a serious risk of fire and burns.
Summary
Product: Vevor Electric Shear J1J-2.5/J1J-3.2
Hazard: 皇冠体育app product presents a serious risk of fire and burns due to counterfeit and noncompliant fuses.
Corrective action: 皇冠体育app product has been recalled from end users. 皇冠体育app import has been rejected at the border and destroyed.
Product information
Type | Electrical appliances and equipment - Electric Shear |
---|---|
Brand | Vevor |
Model | J1J-2.5/J1J-3.2 |
SKU | 921017047431 |
Country of Origin | China |
Counterfeit | Unknown - fuse and cable are counterfeit |
Product description | Electrical shear for cutting sheet metal. |
Product Report and Image |
Hazard
皇冠体育app product presents a serious risk of burns as it contains a counterfeit plug with an insufficient fuse and counterfeit table. 皇冠体育app fuse does not have any granular filler and cannot function properly in the case of a fault with the product or with a surge in current. In the case of a fault, the plug could catch fire and burn users. 皇冠体育app product also requires improvements to labelling and documentation.
皇冠体育app product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016 or the Plugs & Sockets (Safety) Regulations 1994.
Corrective action
皇冠体育app product has been recalled from end users. For further information, access the Vevor recall webpage at:
皇冠体育app import has been rejected at the border and destroyed
Additional information
PSD case number: 2210-0070
Notified by: Local Authority Trading Standards