Product Safety Report: Crytec GS1500 Vulture 15hp woodchipper (2302-0084)

Product Safety Report for Crytec GS1500 Vulture 15hp woodchipper presenting a high risk of injuries.

Summary

Product: Crytec GS1500 Vulture 15hp woodchipper

Hazard: 皇冠体育app product presents a high risk of injuries as the design of the emergency stop trip bar meant that the woodchipper would continue to operate if the wiring of the emergency stop was not connected before use or became disconnected during use.

Corrective action: Withdrawal of the product from the market.

Product information

Type Machinery - Woodchipper
Country of Origin China
Brand Crytec
Model number GS1500
Product Description A red and black woodchipper for branches up to 120mm diameter
Product Report and Image

Hazard

皇冠体育app design of the emergency stop trip bar meant that the woodchipper would continue to operate if the wiring of the emergency stop was not connected before use or became disconnected during use. 皇冠体育app woodchipper was partially assembled as supplied and users were required to carry out final assembly of the woodchipper and connect the emergency stop wiring themselves. 皇冠体育appre were insufficient instructions or warnings in the operator鈥檚 manual increasing the likelihood that the emergency stop would not be connected before use. 皇冠体育app emergency stop trip bar was also not easily distinguishable from the body of the machine by colour. Users may be exposed to shearing hazards and risk of serious injury if drawn into the feed chute in the event the emergency stop fails to operate. 皇冠体育app machine was not CE or UKCA marked and was not accompanied by a Declaration of Conformity.

皇冠体育app machine did not satisfy the requirements of the Machinery Directive or the Supply of Machinery (Safety) Regulations 2008

Corrective action

Withdrawal of the product from the market. 皇冠体育app emergency stop wiring system has been redesigned and operator鈥檚 manual updated.

皇冠体育app manufacturer has contacted existing users to notify them of the risks and to supply additional warning stickers and a new wiring module for retrofitting to the emergency stop. Users who have not been contacted or who require additional assistance fitting the module should contact Crytec for support.

Additional information

PSD case number: 2302-0084

Notified by: Health and Safety Executive

Updates to this page

Published 24 February 2023